Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler
FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!
If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.
Oil Fired Boiler Flue White Smoke
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
A smoke tester and shade scale is useful in evalu- ating smoke density from oil-fired boilers. A measured sample of flue gas is withdrawn from the stack through a filter paper and the smoke spots are com- pared with a standard smoke shade scale.Get Price
The primary measurements required under the Boiler Area Source Rule are flue gas oxygen content and flue gas carbon monoxide content at the high-fire or typical operation load. a) Examine the combustion control components (i.e., the system controlling the air- No. 2 Fuel Oil 2.0 2.2 3.0 3.3 3.0 3.3 7.0 7.6 No. 6 Fuel Oil 2.5 2.8 3.5 3.8 3.5 Get Price
On Kefid 19:34:15.260420 by Jimbo our neighbour had black smoke pouring out of oil boiler flue. our neighbour had black smoke pouring out of oil boiler flue. Since then we have noticed strange burning plastic/ electrical smell in our house.Get Price
1 Aug 2006 The flue gas is white usually when coal is burned completely. However, the flue gas is black when the coal is burned incompletely because of the READ MORE What does white and black smoke signify when it is coming out from . Black smoke indicates that furnace oil is being fired in the boiler .Get Price
Oil-fired boilers should be provided with combustion air in accordance with NFPA31 3 and combustion air openings shall be located at or above the elevation required in IRC Section R322.2.1 per 2015 IRC M1701. Boilers can be vented with a conventional chimney system or through a balanced flue system for direct venting through the wall.Get Price
Jan 27, 2010 · White Smoke, Oil Burner. I have a 2 yr old Laars Max Boiler 75, 90K Btu/hr.Beckett AFII 150 burner. Never noticed until now, white smoke coming out of chimney. Smokes the entire time the burner is on.Get Price
Low nitrogen oils can contain up to 15-20 times less fuel-bound nitrogen than standard No. 2 oil (less than 0.001% fuel-bound nitrogen). When low NOx oil is fired in firetube boilers utilizing flue gas recirculation, NOx reductions of 60%-70% over NOx emissions from standard No. 2 …Get Price
Nov 05, 2019 · Boiler flues are fitted when using combi, regular, and system boilers. The only exception that may apply to a small number of homeowners is a back boiler. This is a type of boiler that is fitted behind a fireplace. If you have a gas boiler behind your fire, the emissions will exit through your chimney, rather than via a boiler flue.Get Price
Oil burner smoke test, combustion air & temperasture adjustment: this article explains and illustrates oil burner smoke testing - a key step in oil burner adjustment for proper operation. An oil burner flame that is too smoky soots-up the heating system leading ultimately to a no-heat call and a clogged furnace or boiler or water heater. An oil burner flame thatGet Price
Oct 12, 2019 · Flue considerations. The position of flue terminals (i.e. where the flue discharges through a wall or roof) is strictly regulated. Oil fired boiler flues must not be terminated beneath windows or where higher parts of the building will affect the draw of the flue or chimney.Get Price
Jan 31, 2020 · Improper burning is the cause of black smoke coming from a boiler. It can also be caused by oil building up in the combustion chamber due to delayed ignition. This is known as 'puff back' and is dangerous as the excess oil can suddenly ignite, causing a shooting flame and potentially splattering oil out of the boiler.Get Price
How to Measure & Set Oil Burner Combustion Air & Smoke Get Price
May 02, 2009 · 846. 2 May 2009. #6. Not quite, Most boilers will plume (white smoke) when they first fire up after laying dormant as any water condensation is heated. But this will stop in the first. 5-10 mins of operation. A condensing boiler is designed to run constantly (assuming correct system temp differential is achieved) in this mode.Get Price
Oil-fired boilers should be provided with combustion air in accordance with NFPA31 3 and combustion air openings shall be located at or above the elevation required in IRC Section R322.2.1 per 2015 IRC M1701. Boilers can be vented with a conventional chimney system or through a balanced flue system for direct venting through the wall.Get Price
May 29, 2021 · Exhaust gasses from the oil-fired furnace and Main engine, pass through the tubes, which are surrounded by boiler water. Separate Uptake provided for Exhaust Gasses and oil-fired smoke. Heavy Changeover valves are fitted, to divert the gasses straight to the funnel. when desired. Alternative Boiler(Alternative type Cochran boiler) If the Get Price
heat exchanger within the boiler and used to preheat the return water. As a result the temperature of the gases leaving the flue of a condensing boiler is typically 50-60°C compared with 120-180°C in a current non-condensing boiler. At the same time an amount of water or 'condensate' is produced. A condensing boiler will always have aGet Price
Gas. Wall Hung. 60/100 mm Horizontal Flue. Installation Manual. Compatible Boilers. Gas. Floor Standing. 60/100 mm Vertical Flue. Installation Manual.Get Price
Aug 08, 2021 · Yellow smoke: If the flue gas column discharged from the chimney is yellow, the flue gas contains a large amount of sulfide, which indicates that the desulfurization equipment of the boiler has not been put into use.Get Price
Jan 01, 1999 · The important difference between oil-fired and gas-fired steam boilers is that the gas-fired boiler uses the natural drafting to carry the heat produced by …Get Price
Buy WiFi Thermostat Programmable Temperature Controller Underfloor Water/Gas Boiler Weather Station Tuya Smart Alexa Voice Control for 87.64 usd in the online store Shop3633016 Store. Compare specifications, photos and reviews of …Get Price
Apr 26, 2016 · Boiler structure CWNS * * -85/65-Q ( Y ) atmospheric gas hot water boiler series automatic fuel Thermal efficiency: ≥ 90%/98% above (condenser) The mixing device is arranged in the boiler backwater imports, return to scour the smoke . There are different high efficiency oil fired hot water boilers on the market.Get Price
Mar 07, 2019 · Plumage is the flue gas that looks like white smoke and wafts around your garden (and your neighbours', which is how problems sometimes arise). india industrial gas boiler | Sitong Wood Biomass Fired Boiler Oil/gas-fired steam boiler – Alfa Laval – Corporate. Oil/gas-fired steam boiler.Get Price
My oil fired boiler is smoking | Screwfix Community ForumGet Price
Answer (1 of 3): There are so many reasons why a boiler fails to operate on Auto. If the boiler operates manually, then that suggests that fan draft, fan vanes, furnace pressure, igniters and main burners are all working. Depending on the age of the BMS, the fault-finding to …Get Price
What Does It Mean When White Smoke Comes Out of My Chimney Get Price
Nov 05, 2019 · Boiler flues are fitted when using combi, regular, and system boilers. The only exception that may apply to a small number of homeowners is a back boiler. This is a type of boiler that is fitted behind a fireplace. If you have a gas boiler behind your fire, the emissions will exit through your chimney, rather than via a boiler flue.Get Price
Apr 08, 2003 · Smoking oil boiler. I have a four year old oil fired boiler, (Weil-McClain), that upon firing puffs back white smoke from around the air band adjustment cam setting. I believe that is what the part is called from looking at the furnace manual. This problem developed all of a sudden one day, not over a period of time. .Get Price
In winter, the white smoke coming from the stack is a) wet steam from combustion of the hydrogen in the fuel When lighting-up an oil fired boiler that employs steam atomizing oil burners, the a) fuel valve is opened before the steam atomizing valve the fireside of the boiler becomes fouled d) flue gas CO value rises e) fuel flow rate Get Price
Jan 15, 2006 · The white 'smoke' that emerges from the flues of condensing boilers is actually clouds of condensate — an effect known as pluming. JULIE MOORE examines them.Today's boilers are markedly different from the products on offer in the past, and there is obviously a need for flue design to change to meet the challenges.Get Price
Sep 03, 2019 · When I fired up the boiler again, there was a considerable amount of black smoke coming out of the flue. The noise that the burner makes wasn't as constant as I seem to remember it. There seemed to be a slight spluttering noise this time when it was ignited. I recently topped up with kerosene for the winter.Get Price