Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler
FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!
If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.
meaning of carryover in steam boiler
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
•Silica –normal saturated steam should be < 20 ppb in most boilers. High pH in the boiler water will reduce silica carryover from the boiler water. Monitor the steam because: •Precipitation of silica forms silicate deposits on the cold end of the turbine that are not water soluble and are very difficult to remove. The deposits may causeGet Price
Fire Tube Boilers Also referred to as smoke tube boilers, shell boilers, package boilers Multiple gas paths - 2, 3 and 4 pass Internal furnace or fire box as the 1st pass Dry back or wet back design Single fuel or dual fuel design Little or no steam separation equipmentGet Price
Carryover is any solid, liquid, or vaporous contaminant that leaves a boiler steam drum with the steam. In boilers operating at pressures of less than 2000 psig, entrained boiler water is the most common cause of steam contamination. The entrained boiler water contains dissolved solids and can also contain suspended solids.Get Price
Yokogawa Eja110a manufacturers & suppliers. Boiler and Feedwater Pump Efficiency Optimization. Wuhan 8 Xi'an 4 Nanchong 1 Beijing 1. Yokogawa Electric Corporation, a leading company in industrial automation IA and technology solutions, recently announced the completion of its storey building eja110 Singapore. Get Price
The use of unreliable equipment can mean no hydrazine or amine additions when the unit is out of action. This can lead to the onset of corrosion in the boilers and subsequent repair costs far outweigh the cost of a reliable chemical dosing pump. …Get Price
Testing Alkalinity In Boiler Water. Alkalinity is a key control parameter for boilers (outside of the prescribed operating range, it can lead to corrosion, caustic metal embrittlement, and carryover) and cooling water systems (where it has a significant effect on chemical treatments for scale and corrosion inhibition).Get Price
This article briefly describes causes and effects of carryover on a steam system. Causes of Carryover. A large number of factors result in carryover in boilers. Some of these factors are-1. Operating pressure. Operating the boiler at pressures significantly lower than design pressures is a cause of carryover.Get Price
1. Priming - This is the ejection of boiler water into the steam take-off and is generally due to one or more of the following: -Operating the boiler with too high a water level. -Operating the boiler below its design pressure; this increases the volume and the velocity of the steam released from the water surface.Get Price
Five Basic Boiler Problems Boiler efficiency can be increased upto 90% by proper maintenance of the systems. Some of the common problems hinder the boiler's ability to produce output to its full capacity. They are as under- 1. Priming: When the steam is produced in the boiler, some droplets of water get carried away with the … Top 5 Basic Industrial Boiler Problems & Their Solutions …Get Price
May 14, 2005 · My guess is that condensate carryover is caused by sudden drop in steam pressure that entrains unvaporized condensate. Try to slow the rate of increase of steam demand from the boiler (slow the application of load to the boiler). RE: carryover in boilers. davefitz (Mechanical) 27 Apr 05 09:29. Carryover has many possible causes.Get Price
Carryover of boiler water, resulting from inadequate steam-water separation equipment in the boiler, caused this turbine deposit problem. The nature of silica deposits found on turbine blades varies greatly. Table 18-1 lists a number of silica compounds that have been identified in various studies of turbine blade deposition.Get Price
Jan 22, 2022 · Steam boilers are imperative in the process and manufacturing sector to generate high-quality steam. Plant managers monitor various factors to ensure hassle-free operations. One of such important factors is steam pressure. An oversized steam boiler utilizing saturated steam opt for reducing the steam pressure. Steam pressure is determined by the factors like the …Get Price
2/18/2014 3 Cheat Sheet - Reactions • Bicarbonate Break: Na 2 HCO 3 + HEAT Na 2 CO 3 + CO 2 + H 2 O • Developed Alkalinity: Na 2 CO 3 + HEAT + 2H 2 O 2NaOH + CO 2 + H 2 O • Brining Reactions: CaCl + Boiler Water CaSO 4 + CaSiO 3 • Phosphate Reactions: …Get Price
This preview shows page 13 - 15 out of 44 pages. a) steam carryover b) corrosion c) scale formation d) none of the above Removal of dissolved gases from the boiler feed water is called a) degasification b) deaeration c) deoxidation d) none of the above Enthalpy of evaporation of steam will be highest at a) 2 kgs/cm 2 b) 8 kgs/cm 2 c) 12 kgs/cm Get Price
May 02, 2000 · BASIC WATER TREATMENT OF STEAM BOILERS Steve Kenny and Dave Pope Chemco Water Technology Vancouver, WA This is a brief discussion on low-pressure steam boiler chemistry. It provides dry kiln boiler operators the tools to maintain an efficient and effective boiler chemistry program.Get Price
The total carryover of boiler water impurities and conditioning chemicals in drum boilers determines the chemical purity of the steam. Carryover is a combination of two factors: vaporous carryover, due to the inherent volatility of the constituents in the boiler water, and mechanical carryover of droplets of boiler water into the steam.Get Price
Apr 30, 2021 · First, as a general rule, carryover stocks are, held in countries that have lower carrying costs, which are probably exporting countries because they enjoy lower prices. The damaging condition where water droplets are carried out of a steam boiler along with the dry steam. Derived terms . HCO: hearing carryover; Anagrams . overcarryGet Price
Remember also, any moisture carryover with the steam is an additional heat loss through the steam line. Prevention and Treatment for Carryover-Foaming and Priming There are two kinds of solids present in most boiler water-the dissolved solids, or substances that are in solution, and suspended solids.Get Price
Aug 07, 2014 · Mechanisms. Carryover also known as priming is any solid, liquid or vaporous contaminant that leaves a boiler with the steam. In low/medium pressure boilers (<100 bar) entrained boiler water is the most common cause of steam contamination. Both mechanical factors such as boiler design, high water levels, load characteristics and chemical factors such …Get Price
Jul 30, 2019 · Boiler water carry-over is the contamination of the steam with boiler-water solids. Priming is the carryover of varying amounts of droplets of water in the steam (foam and mist), which lowers the energy efficiency of the steam and leads to the deposit of salt crystals on the super heaters and in the turbines.Get Price
May 09, 2016 · Boiler manufacturers guarantee a maximum percent carryover limit of 0.05% to 0.10%. The level of steam contamination is measured as percent moisture and parts per million (ppm) solids. Steam quality is expressed as percent moisture or conversely as percent dryness. Most boilers are capable of producing steam that is 99% dry (1% moisture) at a Get Price
Aug 28, 2016 · When using boilers for an industrial plant and process, one of the most important things to implement is the appropriate treatment of the boiler feed water before it has a chance to scale and corrode equipment.Before beginning any process with a boiler, understanding the makeup and return water chemistry/characteristics, the manufacturer's requirements for the …Get Price
Get superior quality steam boiler manufacturers list at Alibaba.com to power your operations. Get the exclusive range of top-grade steam boiler manufacturers list at …Get Price
What is Carryover | Causes of CarryoverGet Price
A high water condition in the boiler feed pump reciever. A time clock. Definition. A low water condition in the boiler. Term. Water is usually supplied to the boilers that are installed in large commercial systems or to a system with a condensate return problem or to fire tube boilers by a: Condensate receiver pump.Get Price
In boilers with deaerated, mildly alkaline conditions, the surfaces of clean mild steel react with water to form magnetite and/or haematite Magnetite, Fe. 3. O. 4 (black, stable in more reducing conditions. Haematite, Fe. 2. O. 3 (red/brown, stable in more oxidising conditions). At boiler operating, these oxides are compact, non porous and Get Price
Boiler Carryover in Steam Generating Systems | Water Get Price
6. If, prior to reducing boiler steam pressure, the boiler is already having carryover issues, these should be addressed before considering reducing the boiler steam pressure. Steam System Losses and Savings Through Pressure Reduction . A List of Boiler and Steam System LossesGet Price
The steam boiler is the heartbeat of your operation, and issues with carryover can cost you heavily in terms of inconsistent products and lost production time. By taking the time to learn proper steam boiler treatment and operating it with care, …Get Price
I was reading through the wet head site the other night; is there a "better" brand for residential steam boilers? I never paid attention to the "wideness" factor of the boiler castings, but it does make sense. Also I never really paid attention to the (I forget the term) steam capacity, or in other words the length of time the boiler will Get Price